Applications: Real-world examples


Pelco-D Protocol Tutorial / Examples

Pelco-D is the popular PTZ camera control protocol used in the CCTV industry (Click here to visit Pelco's website).

This page will explain the following topics in details:
1) The format of Pelco-D
2) How to calculate the checksum byte by using 232Analyzer
3) Pelco-D command string examples
4) How to use 232Analyzer to control the Pelco-D cameras
5) Have fun playing with 232Analyzer and Pelco-D cameras

After reading this page and testing the camera with the 232Analyzer software , you should be able to understand the ease of using the Pelco-D protocol, and control any Pelco-D cameras in five minutes' time.

Notes:
1) Before you can control any Pelco-D cameras, you need to prepare the following items:
- A PC running 232Analyzer program
- A RS-232 port (or USB/RS-232 converter)
- A RS-232/RS-485 converter
2) Make sure your COM port settings in the 232Analyzer program matches with camera's settings (Pelco-D cameras use No parity, 8 Data bits and 1 Stop bit, baud rate depends on your camera setting)

(Click here to download the 232Analyzer FREE Version. Click here to download Pelco-D/P device profiles)

1) The format of Pelco-D

Pelco-D consists of 7 hexadecimal bytes (all byte data used in this page are in Hexadecimal format unless otherwise noted)

Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7
Sync Camera Address Command 1 Command 2 Data 1 Data 2 Checksum
  • Byte 1 (Sync) - the synchronization byte, fixed to FF

  • Byte 2 (Camera Address) - logical address of the camera being controlled (Address 1 is 01)

  • Byte 3 & 4 (Command 1 and 2) are shown below

  • Byte 5 (Data 1) - pan speed, range from 00 (stop) to 3F (high speed) and FF for "turbo" speed (the maximum pan speed that the device can go)

  • Byte 6 (Data 2) - tilt speed, range from 00 (stop) to 3F (maximum speed)

  • Byte 7 (Checksum) - sum of bytes (excluding the synchronization byte), then modulo 100 (Decimal code: 256)

Command 1 and 2 details

Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Command 1 Sense Reserved Reserved Auto / Manual Scan Camera On/Off Iris Close Iris Open Focus Near
Command 2 Focus Far Zoom Wide Zoom Tele Tilt Down Tilt Up Pan Left Pan Right Fixed to 0

Example (Command 2): Pan Left - 0 0 0 0 0 1 0 0, which equals to 04 (both hexadecimal and decimal) Some other commands

Command Byte 3 Byte 4 Byte 5 Byte 6
Go to Preset 00 07 00 01 to FF
Set Zoom Speed 00 25 00 00 to 33
Set Focus Speed 00 27 00 00 to 33
Alarm Ack. 00 19 00 Alarm no.

2) How to calculate the checksum byte by using 232Analyzer

Suppose you are controlling camera 1 (address 1) to pan left at high speed, the command string of the first 6 bytes would be: FF 01 00 04 3F 00

Step 1: Go to "Checksum Calculator" pane, choose "Hex" as "Operands format" and "+" as Operator. Then take out the first byte FF and key in all other bytes in the "Input operands" box. Remember to add "," after each byte of data. You will then get the result of "44"

Step 2: Change Operator to ",Mod", and key in the previous result ("44") and modulo parameter "100" in the "Input operands" box, remember to add "," after each byte of data. You will then get the result of "44" in "Remainder (Mod)" box.

"44" would be the result of checksum, now the full string of pan left at high speed command would be FF 01 00 04 3F 00 44

3) Pelco-D command string examples

Camera Address: 1 Pan Left at high speed: FF 01 00 04 3F 00 44 Pan Right at medium speed: FF 01 00 02 20 00 23 Tilt Up at high speed: FF 01 00 08 3F 00 48 Tilt Down at medium speed: FF 01 00 10 20 00 31 Stop all actions (Pan/Tilt/Zoom/Iris etc.): FF 01 00 00 00 00 01 Note: there will be no response from cameras in Pelco-D protocol

4) How to use 232Analyzer to control the Pelco-D cameras

Suppose you are controlling camera address no. 1 to pan left at medium speed (command string: FF 01 00 04 20 00 25)

Way 1: From the command pane - choose "Hex" as the TX data format and key in the command string "FF,01,00,04,20,00,25," in the input box as shown below. Then click on the "Send" button. The command will then be sent out immediately and you will notice the camera panning left continuously.

Note: If you are using the FREE Version, choose "Dec" as TX data format and key in "255,1,0,4,32,0,37,"

Way 2: From Programmable buttons

Download and unzip the Pelco-DP.zip file, then open "Pelco-D.232" file from 232Analyzer program. When you click on the first button "Lef", the command will be sent out after 500ms

5) Have fun playing with 232Analyzer and Pelco-D cameras

The programmable buttons 1 to 8 will trigger the camera's action continuously. To stop, you have to send out the "Stop" command "FF 01 00 00 00 00 01" (or "255 01 00 00 00 00 01" Decimal format) to the camera.

"Pelco-D.232" file allows you to send two (2) commands with the click of a button, e.g. when you click on "Lef" button on the second row (button no. 9), the camera will pan left for 500ms and then stop. This is because button no. 9 is linked to button 17, which stores the "Stop" command. (Note: Programmable buttons 9 to 16 will trigger the camera's action for 500ms and will stop automatically).

You may program it in such a way that the camera pans left for 500ms, stops, tilts up for 1000ms, stops, tilts down for 500ms, and then pans right continuously. All sorts of actions can be done through "Programmable Buttons" or "Macros" functions.

USB Serial RS232 RS485 RS422 TTL Ethernet Fiber Optic Converter Adapter Repeater Isolator Analyzer